01

A document is not lost if a workstation stops

An active/standby group of Print Clients keeps the same print destination available even when a workstation is unreachable, disabled, or loses its authorization. If the leader is no longer available, a standby automatically takes over leadership and receives pending jobs, without manual intervention.

02

The path of a job from creation to printing

Steps

  1. The business system creates the PDF and specifies the exact local queue.
  2. The gateway keeps the job separated by company and group.
  3. The group leader takes charge of the job atomically.
  4. The client downloads the PDF and sends it to the specified local queue.
  5. The PRINTED, FAILED, or DELIVERY_UNKNOWN states make the outcome verifiable.

03

What you need before relying on failover

Prerequisites

  • At least two workstations that can reach the same printers.
  • Login and MFA completed for each client, authorized separately.
  • Identical exact local queue names on every workstation in the group.
  • Different numeric priorities assigned in the Nebulas Portal.

04

Hypothetical example: a workstation stops mid-shift

Hypothetical scenario: while downloading a document, the preferred workstation stops. If the job is still being downloaded, once the recovery lease expires it may return to pending and be picked up by the new leader. If the PDF had already been delivered to the local spooler, the system cannot know for certain how much paper was produced: the job moves to DELIVERY_UNKNOWN and is not automatically reprinted, precisely to avoid duplicate copies.

05

Checks to perform before and after failover

  • Verify heartbeat, status, detected queues, and active client before production use.
  • Check that the queue specified by the job exists with an identical name on the active client.
  • A job missing its queue stays pending: it is never redirected to another printer.
  • Verify the physical outcome of a DELIVERY_UNKNOWN job before deciding how to proceed.

06

How Nebulas Print Client governs continuity

Each workstation keeps its own identifier and its own authorization; the Print Gateway assigns the group a single leader through a renewable lease. Operations that take charge of a job check both the active leader and the lease epoch, so a previously isolated leader cannot start new jobs after handover to a standby. An administrator can disable, remove, or deauthorize a client from the Nebulas Portal: the gateway excludes the workstation and another eligible member takes over leadership.

07

How to configure an active/standby group

Steps

  1. Install Nebulas Print Client on at least two eligible workstations.
  2. Complete login and MFA in the browser and authorize each PC separately.
  3. Verify that every workstation exposes the same exact queue names.
  4. Assign the clients to the same group and set different priorities in the Portal.
  5. Check heartbeat and active client before using the group in production.

08

The next step

Check the status of your print group in the Nebulas Portal: heartbeat, active leader, and detected queues on every workstation, before considering it production-ready.

FAQ

Frequently asked questions

Can failover cause a document to print twice?

No: a job with an uncertain physical outcome becomes DELIVERY_UNKNOWN and is not automatically reprinted, precisely to avoid possible duplicates after a handover between clients.

What happens if the requested queue does not exist on the active client?

The job stays pending to allow the configuration to be corrected; the system never diverts it to a different printer than the one specified.

Can an administrator exclude a workstation from the group?

Yes, they can disable, remove, or deauthorize a client from the Nebulas Portal: the gateway excludes the workstation and another eligible member takes over leadership.

✓